BF Silent 100TH Aérateur

Aérateur axial temporisé avec humidistat 230V - Ø100mm

N° article: 98623

BF SILENT FANS

APPLICATION

 

Ideal for air-extraction in bathroom, toilet and small/medium premises. Suitable to extract stale air directly to the outside or through short length ducting. Units can be wall/panel, ceiling and window mounted.

SPECIFICATION

 

Casing made of high quality ABS provides long lasting shock-proof and robust construction. The unit are finished in white RAL 9010 and are UV resistant.

Unique design winglet-type impeller, providing enhanced aerodynamic properties, low noise and increased efficiency.

Single-phase induction motors with integral thermal protection, mounted on high quality ball bearings. Suitable for continuous and intermittent running.

FEATURES & BENEFITS

 

IPX4 protection degree

Aesthetic front flat cover for modern interior design easily removed for cleaning.

Rigid optimised spigot support preventing distortion with strengthened guard and design to maximise airflow.

Integral back-draught shutter to prevent air flowing back into the room when the fan is off.

Low power consumption: 100mm model has less than 8 watts opearating power consumption for energy saving.

Totally recyclable plastic components, environmentally friendly. Double insulated: no earth connection is required.

Tested to the latest standards: units are tested in the TÜV Rheinland recognised laboratory, meaning accurate, up to date information on electrical safety, performance and noise level that can be relied upon. Designed and manufactured in accordance with EN60335-2-80 (Low Voltage Directive) and the EMC Directive (Electromagnetic Compatibility).

VERSIONS

 

Standard

 

The fan is operated via a separate ON/OFF switch or the light switch.

Run-on timer

 

The fan is equipped with a timer circuit adjustable from ± 1‘ to 25’. Operation: after switching off, the fan continues to run for the pre-set period of time.

Humidistat & timer

The fan is provided with an electronic circuit having a humidity sensor on board (adjustable from 50% to 95% RH) and a timer, adjustable from ± 1’ to 25’. Operation: when the percentage of relative humidity is higher/lower than the pre-set threshold, the fan is automatically activated/ deactivated. After switching off, the fan continues to run for the pre-set period of time.

EcoDesign

EcoDesign
Conformité ErP 2018
Catégorie d’unité RVU
Variateur MSD ou VSD externes
Type d’unité UVU
Type de récupérateur de chaleur Aucun
Ratio de température (UVU) Non applicable
Qv nom 0,0161 m³/s
Puissance nominale 0,009 kW
Pression nominale 13 Pa
Efficacité du ventilateur 2,5 %
CTA standard
Conformité ErP 2018
Moyenne SEC -10,58 kWh/(m².a)
Froid SEC -26,98 kWh/(m².a)
Chaud SEC -1,19 kWh/(m².a)
Class SEC C
Catégorie d’unité RVU
Type d’unité UVU
Variateur MSD ou VSD externes
Type de récupérateur de chaleur Aucun
Ratio de température (UVU) Non applicable
Qv max 58 m³/h
P max 9 W
Qv ref 0,0114 m³/s
Pression réf. 7 Pa
SPI 0,21 W/(m³/h)
CTRL 1
Divers 1,1
Valeur x 1,5
Fuite externe Non applicable
Moyenne AEC 263 kWh
Froid AHS 263 kWh
Chaud AEC 263 kWh
Moyenne AHS 17 kWh/a
Froid AHS 34 kWh/a
Chaud AHS 8 kWh/a
Unité avec contrôle local
Conformité ErP 2018
Moyenne SEC -24,86 kWh/(m².a)
Froid SEC -51,92 kWh/(m².a)
Chaud SEC -9,35 kWh/(m².a)
Class SEC C
Catégorie d’unité RVU
Type d’unité UVU
Variateur MSD ou VSD externes
Type de récupérateur de chaleur Aucun
Ratio de température (UVU) Non applicable
Qv max 58 m³/h
P max 9 W
Qv ref 0,0114 m³/s
Pression réf. 7 Pa
SPI 0,21 W/(m³/h)
CTRL 0,65
Divers 1,1
Valeur x 1,5
Fuite externe Non applicable
Moyenne AEC 138 kWh
Froid AEC 138 kWh
Chaud AEC 138 kWh
Moyenne AHS 28 kWh/a
Froid AHS 55 kWh/a
Chaud AHS 13 kWh/a

Paramètres techniques

Données nominales
Tension (nominale) 230 V
Fréquence 50 Hz
Phases 1~
Puissance installée 8 W
Intensité 0,067 A
Vitesse de rotation 2 350 tr/min
Débit d'air [m³/h] max 83 m³/h
Température air en mouvement max 50 °C
Données acoustiques
Pression sonore à 3 m (champ libre) 26 dB(A)
Protection/Classification
Indice de protection, moteur IPX4
Classe d'isolation B
Données selon ErP
Classe énerg., unité standard C
Classe énerg., demande locale E
Dimensions et poids
Conduit Circul d'aspiration 100 mm
Poids 0,73 kg
Autres
Type de moteur AC
Images Performance - BF Silent 100TH Aérateur - systemair
Images Dimensions - BF Silent 100TH Aérateur - systemair
(mm)