BF Silent 100HT

Centrifugal bathroom fan, <125W

Art. no.: 98623

BF SILENT FANS

APPLICATION

 

Ideal for air-extraction in bathroom, toilet and small/medium premises. Suitable to extract stale air directly to the outside or through short length ducting. Units can be wall/panel, ceiling and window mounted.

SPECIFICATION

 

Casing made of high quality ABS provides long lasting shock-proof and robust construction. The unit are finished in white RAL 9010 and are UV resistant.

Unique design winglet-type impeller, providing enhanced aerodynamic properties, low noise and increased efficiency.

Single-phase induction motors with integral thermal protection, mounted on high quality ball bearings. Suitable for continuous and intermittent running.

FEATURES & BENEFITS

 

IPX4 protection degree

Aesthetic front flat cover for modern interior design easily removed for cleaning.

Rigid optimised spigot support preventing distortion with strengthened guard and design to maximise airflow.

Integral back-draught shutter to prevent air flowing back into the room when the fan is off.

Low power consumption: 100mm model has less than 8 watts opearating power consumption for energy saving.

Totally recyclable plastic components, environmentally friendly. Double insulated: no earth connection is required.

Tested to the latest standards: units are tested in the TÜV Rheinland recognised laboratory, meaning accurate, up to date information on electrical safety, performance and noise level that can be relied upon. Designed and manufactured in accordance with EN60335-2-80 (Low Voltage Directive) and the EMC Directive (Electromagnetic Compatibility).

VERSIONS

 

Standard

 

The fan is operated via a separate ON/OFF switch or the light switch.

Run-on timer

 

The fan is equipped with a timer circuit adjustable from ± 1‘ to 25’. Operation: after switching off, the fan continues to run for the pre-set period of time.

Humidistat & timer

The fan is provided with an electronic circuit having a humidity sensor on board (adjustable from 50% to 95% RH) and a timer, adjustable from ± 1’ to 25’. Operation: when the percentage of relative humidity is higher/lower than the pre-set threshold, the fan is automatically activated/ deactivated. After switching off, the fan continues to run for the pre-set period of time.

Ecodesign

Ecodesign
ErP compliance 2018
Unit category RVU
Drive External MSD or VSD
Unit type UVU
Heat recovery type None
Temperature ratio (UVU) Not applicable
qv nom 0.0161 m³/s
P nom 0.009 kW
Ps nom 13 Pa
Fan efficiency 2.5 %
Basic unit
ErP compliance 2018
SEC Average -10.58 kWh/(m².a)
SEC Cold -26.98 kWh/(m².a)
SEC Warm -1.19 kWh/(m².a)
SEC Class C
Unit category RVU
Unit type UVU
Drive External MSD or VSD
Heat recovery type None
Temperature ratio (UVU) Not applicable
qv max 58 m³/h
P max 9 W
qv ref 0.0114 m³/s
Ps ref 7 Pa
SPI 0.21 W/(m³/h)
CTRL 1
MISC 1.1
x-value 1.5
External Leakage Not applicable
AEC average 263 kWh
AHS Cold 263 kWh
AEC warm 263 kWh
AHS Average 17 kWh/a
AHS Cold 34 kWh/a
AHS Warm 8 kWh/a
Units with local demand control
ErP compliance 2018
SEC Average -24.86 kWh/(m².a)
SEC Cold -51.92 kWh/(m².a)
SEC Warm -9.35 kWh/(m².a)
SEC Class C
Unit category RVU
Unit type UVU
Drive External MSD or VSD
Heat recovery type None
Temperature ratio (UVU) Not applicable
qv max 58 m³/h
P max 9 W
qv ref 0.0114 m³/s
Ps ref 7 Pa
SPI 0.21 W/(m³/h)
CTRL 0.65
MISC 1.1
x-value 1.5
External Leakage Not applicable
AEC average 138 kWh
AEC cold 138 kWh
AEC warm 138 kWh
AHS Average 28 kWh/a
AHS Cold 55 kWh/a
AHS Warm 13 kWh/a

Technical parameters

Nominal data
Voltage (nominal) 230 V
Frequency 50 Hz
Phases 1~
Input power 8 W
Input current 0.067 A
Impeller speed 2,350 rpm
Air flow [m³/h] max 83 m³/h
Temperature of transported air max 50 °C
Sound data
Sound pressure level at 3m (free field) 26 dB(A)
Protection/Classification
Enclosure class, motor IPX4
Insulation class B
Data according to ErP
Energy class, Basic unit C
Energy class, Local demand E
Dimensions and weights
Duct dimension; Circular, inlet 100 mm
Weight 0.73 kg
Others
Motor type AC
Images Performance - BF Silent 100HT - systemair
Images Dimensions - BF Silent 100HT - systemair
(mm)